Show simple item record

dc.contributor.advisorBRÁS, DIOGO JOSÉ MONTEIRO
dc.contributor.authorBorella, Alessandro
dc.date.accessioned2023-11-22T13:35:32Z
dc.date.available2023-11-22T13:35:32Z
dc.date.issued2023
dc.identifier.urihttp://hdl.handle.net/20.500.11816/4380
dc.description.abstractIntrodução: Na prática clínica diária, a utilização de instrumentos colorimétricos oferece a possibilidade de gerir aspetos de cor facilitando a escolha, comunicação, reprodução e controlo da cor nas restaurações (1). Existem duas abordagens possíveis para a escolha da cor: o método visual e o método tecnológico instrumental. Objetivo: O objetivo desta revisão sistemática integrativa é analisar e comparar a confiabilidade da correspondência de cores visual e instrumental e a taxa de concordância dos diferentes métodos de medição de cor dental. Materiais e métodos: Foi realizada uma pesquisa bibliográfica na base de dados PubMed (via National Library of Medicine). Foi utilizada a estratégia PICO e foram redigidos critérios de inclusão e de exclusão para escolher os artigos úteis para o presente estudo. Resultados: Foram analisados quinze artigos caso-controlo onde dois estudos tiveram uma amostra em vitro e treze em vivo. Nove artigos analisaram o método visual e catorze instrumentais. Discussão: Foi relatada uma relevância altamente significativa na confiabilidade no espectrofotómetro e no scanner intraoral comparado com a escala visual de cor. Conclusão: Entre os métodos instrumentais o scanner intraoral 3Shape Trios e o espetrofotómetro (EFT) VITA Easyshade exibiram excelente confiabilidade e correspondência de cores significativamente melhor comparados com outros modelos de avaliação visual e instrumental.pt_PT
dc.description.abstractIntroduction: In daily clinical practice, the use of colorimetric instruments offers the possibility of managing color aspects, facilitating choice, communication, reproduction and control of color in restorations(1). There are two possible approaches to color choice: the visual method and the instrumental technological method. Objective: The aim of this integrative systematic review is to analyze and compare the reliability of visual and instrumental color matching and the concordance rate of different methods of measuring dental color. Materials and methods: A bibliographic search was carried out in the PubMed database (via the National Library of Medicine). The PICO strategy was used and inclusion and exclusion criteria were written to choose useful articles for the present study. Results: Fifteen case-control articles were analyzed, where two studies had a sample in vitro and thirteen in vivo. Nine articles analyzed the visual method and fourteen instrumental ones. Discussion: A highly significant relevance in the reliability of the spectrophotometer and the intraoral scanner compared to the visual color scale was reported. Conclusion: Among the instrumental methods, the 3Shape Trios intraoral scanner and the VITA Easyshade spectrophotometer exhibited excellent reliability and significantly better color matching compared to other visual and instrumental evaluation models.pt_PT
dc.language.isoporpt_PT
dc.rightsinfo:eu-repo/semantics/openAccesspt_PT
dc.subjectDental colorpt_PT
dc.subjectShades selectionpt_PT
dc.subjectColor perception testpt_PT
dc.subjectDental estheticpt_PT
dc.subjectSpectrophotometer shade matchingpt_PT
dc.subjectInstrumental methodspt_PT
dc.subjectDentistrypt_PT
dc.titleSeleção de cor em dentisteria. Confiabilidade da correspondência de cores visual e instrumentalpt_PT
dc.typeinfo:eu-repo/semantics/masterThesispt_PT
dc.identifier.tid203359038pt_PT
thesis.degree.nameMestrado em Medicina Dentáriapt_PT


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record