dc.contributor.advisor | SANTOS, PRIMAVERA DA CONCEIÇÃO MARTINS DE SOUSA | |
dc.contributor.author | Samti, Lamiae Es | |
dc.date.accessioned | 2024-11-07T12:18:25Z | |
dc.date.available | 2024-11-07T12:18:25Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11816/4572 | |
dc.description.abstract | Introdução: Os mini-implantes ortodônticos (MIs), nomeadamente os de Ti-6Al-4V, são cada vez mais utilizados no ramo da ortodontia, proporcionando bons resultados de tratamento. Frequentemente, após a colocação dos MIs, os ortodontistas recorrem à prescrição de colutórios para evitar risco de inflamação/infeção e garantir uma boa estabilidade, otimizando o resultado do tratamento final.
Objetivo: Esta revisão sistemática foi conduzida com o intuito de analisar os efeitos do colutório de clorexidina (CHX) e do colutório de fluoreto de sódio (NaF) na superfície dos MIs de liga de titânio e analisar a citotoxicidade, a corrosão e a libertação de iões.
Matérial e métodos: Foi efetuada uma pesquisa nas bases de dados PubMed, Science Direct e Google Scholar entre janeiro de 2008 e dezembro de 2023, utilizando palavras-chave.
Resultados: Foram selecionados, para realização desta revisão sistemática, 12 artigos em função dos critérios de inclusão e exclusão.
Discussão: O NaF parece ter efeitos mais negativos do que a CHX nos MIs, quer tendo em conta a quantidade de iões libertados, quer em termos da alteração da camada superficial, com maior corrosão e destruição da microestrutura superficial na maioria dos estudos.
Conclusão: Os colutórios com NaF alteram a camada superficial dos MIs causando corrosão e libertação de iões que podem ser citotóxicos. Os colutórios com CHX estão associados a bons resultados provocando uma alteração mínima da camada superficial e uma baixa libertação de iões na superfície dos MIs. | pt_PT |
dc.description.abstract | Introduction: Orthodontic mini-screws (MSs), particularly those made of Ti-6Al-4V, are increasingly used in orthodontics, providing good treatment results. Often, after the placement of MSs, orthodontists prescribe mouthwash to avoid the risk of inflammation/infection and ensure good stability, optimizing the final treatment result.
Objectives: The aim of this review is to analyse the effects of chlorhexidine mouthwash (CHX) and sodium fluoride mouthwash (NaF) on the surface of titanium alloy MSs and analyse cytotoxicity, corrosion and the release of ion caused.
Materials and methods: A search was carried out in the PubMed, Science Direct and Google Scholar databases between January 2008 and December 2023 using keywords.
Results: 12 articles were selected for the study according to the exclusion and inclusion criteria.
Discussion: NaF seems to have more negative effects than CHX on MSs, both in terms of the number of ions released and in terms of altering the surface layer, with greater corrosion and destruction of the surface microstructure in most studies.
Conclusion: Mouthwash with NaF alters the surface layer of the MSs, causing corrosion and the release of ions which can be cytotoxic. Mouthwash with CHX gives good results, causing minimal alteration to the surface layer of the MSs and low release of the ions contained. | pt_PT |
dc.language.iso | por | pt_PT |
dc.rights | info:eu-repo/semantics/openAccess | pt_PT |
dc.subject | Dental implants | pt_PT |
dc.subject | Orthodontic Anchorage Procedures | pt_PT |
dc.subject | Chlorhexidine | pt_PT |
dc.subject | Sodium fluoride | pt_PT |
dc.subject | Corrosion | pt_PT |
dc.subject | Ions | pt_PT |
dc.title | Avaliação do efeito dos colutórios nos miniimplantes de liga de titânio: Revisão sistemática | pt_PT |
dc.type | info:eu-repo/semantics/masterThesis | pt_PT |
dc.identifier.tid | 203701208 | pt_PT |
thesis.degree.name | Mestrado em Medicina Dentária | pt_PT |